Journal of Health Sciences and Medicine

Journal of Health Sciences and Medicine

The effect of phosphorolcoline-coated cardiopulmonary by-pass circuits on morbidity and mortality in patients with congenital open cardiac surgery

Yazarlar: Ali BOLAT, Suleyman SURER, Özlem GÜLBAHAR, Esef BOLAT, Yıldırım GÜLTEKİN, Ali KUTSAL

Cilt 4 , Sayı 2 , 2021 , Sayfalar 160 - 165

Konular:Sağlık Bilimleri ve Hizmetleri

DOI:10.32322/jhsm.854196

Anahtar Kelimeler:Phosphorylcholine coated oxygenator,Congenital heart surgery,Cardiopulmonary bypass,Inflammation

Özet: Objective: Our aim in this study is to investigate the relationship between mortality and morbidity of phosphorylcholine coated oxygenator circuit used in heart-lung machine in congenital open heart surgery operations. Materials and Methods: The study was conducted in Dr. Sami Ulus Child Diseases Training and Research Hospital Cardiovascular Surgery Clinic between 2008-2009. 30 congenital heart patients were included. The patients were divided into 2 groups of 15 people. In one of the groups, a phosphorylcholine coated oxygenator circuit was used in the heart lung machine (Group P). In the other group, a standard oxygenator circuit was used (Group C).Congenital heart surgery was performed for 19 Ventricular Septal Defects (VSD), 5 Secundum Atrial Septal Defects (ASD), 3 Primum ASD, 2 Mitral insufficiency and 1 Discret subaortic membrane. Extubation times, intensive care and discharge times, 24-hour drainage follow-up, inotropic drug use, blood and fresh frozen plasma (FFP) transfusion amount, aspartate aminotransferase, alanine aminotransferase, creatine phosphokinase-MB, urea, blood urea nitrogen, creatinine, white cell number of platelets, lactate dehydrogenase, albumin, total protein, C-reactive protein, prothrombin time, partial thromboplastin time, fibrinogen, D-dimer, C5a and elastase levels were compared perioperatively. Results: In the study, it was determined that the discharge time was shorter in Group P. It was found that the increase in d-dimer values with fibrinogen was less in Group P. These were found to be statistically significant (p <0.05). There was no significant difference between groups in other parameters (p> 0.05). There was no mortality in either group. Conclusion: In this study, phosphorylcholine-coated oxygenator did not significantly reduce the inflammatory response during cardiopulmonary by-pass (CPB). There was no difference between the two groups in terms of morbitidity and mortality.However, the fact that fibrinogen values, which are the acute phase reactants, are lower than the control group and the increase in d-dimer values remain limited may be important in terms of hemocompatibility of the phosphorylcholine coated circuit.


ATIFLAR
Atıf Yapan Eserler
Henüz Atıf Yapılmamıştır

KAYNAK GÖSTER
BibTex
KOPYALA
@article{2021, title={The effect of phosphorolcoline-coated cardiopulmonary by-pass circuits on morbidity and mortality in patients with congenital open cardiac surgery}, volume={4}, number={160–165}, publisher={Journal of Health Sciences and Medicine}, author={Ali BOLAT,Suleyman SURER,Özlem GÜLBAHAR,Esef BOLAT,Yıldırım GÜLTEKİN,Ali KUTSAL}, year={2021} }
APA
KOPYALA
Ali BOLAT,Suleyman SURER,Özlem GÜLBAHAR,Esef BOLAT,Yıldırım GÜLTEKİN,Ali KUTSAL. (2021). The effect of phosphorolcoline-coated cardiopulmonary by-pass circuits on morbidity and mortality in patients with congenital open cardiac surgery (Vol. 4). Vol. 4. Journal of Health Sciences and Medicine.
MLA
KOPYALA
Ali BOLAT,Suleyman SURER,Özlem GÜLBAHAR,Esef BOLAT,Yıldırım GÜLTEKİN,Ali KUTSAL. The Effect of Phosphorolcoline-Coated Cardiopulmonary by-Pass Circuits on Morbidity and Mortality in Patients with Congenital Open Cardiac Surgery. no. 160–165, Journal of Health Sciences and Medicine, 2021.