A Journal of Analytical Chemistry and Chemical Analysis

A Journal of Analytical Chemistry and Chemical Analysis

Hydrophilic Interaction Liquid Chromatography Coupled with Fluorescence Detection (HILIC-FL) for the Quantitation of Octreotide in Injection Forms

Yazarlar: Eleni Doulou, Marina Kalomiraki, Anthi Parla, Kyriaki Thermos, Nikos A. Chaniotakis, Irene Panderi

Cilt 2 , Sayı 4 , 2021 , Sayfalar 121-129

Konular:-

DOI:10.3390/analytica2040012

Anahtar Kelimeler:Hydrophilic interaction liquid chromatography,Fluorescence detection,Octreotide,Octreotide acetate,SMS 201-995,Somatostatin

Özet: Octreotide is a synthetic cyclic octapeptide analogue of somatostatin-14. It is mainly administered for the treatment of acromegaly, severe diarrhea, and neuroendocrine neoplasias. In this work, a hydrophilic interaction liquid chromatography (HILIC) method with fluorescence (FL) detection was developed and validated for the quantitation of octreotide in solutions for injection. Chromatographic separation was performed on an XBridge®-HILIC analytical column under isocratic elution with a short chromatographic run time of less than 10 min. The mobile phase consisted of ammonium bicarbonate 8.6 mM (pH 8.1)/acetonitrile 35/65 ( v/v). The high sensitivity and selectivity of the fluorescence detection, with the excitation wavelength (λ excitation) set at 280 nm and the emission wavelength set at (λ emission) 330 nm, enabled a simple sample preparation procedure that included only dilution steps. The calibration curve showed good linearity with a correlation coefficient greater than 0.998. The method was successfully applied to the analysis of commercially available octreotide injection forms.


ATIFLAR
Atıf Yapan Eserler
Henüz Atıf Yapılmamıştır

KAYNAK GÖSTER
BibTex
KOPYALA
@article{2021, title={Hydrophilic Interaction Liquid Chromatography Coupled with Fluorescence Detection (HILIC-FL) for the Quantitation of Octreotide in Injection Forms}, volume={2}, number={121–129}, publisher={A Journal of Analytical Chemistry and Chemical Analysis}, author={Eleni Doulou,Marina Kalomiraki,Anthi Parla,Kyriaki Thermos,Nikos A. Chaniotakis,Irene Panderi}, year={2021} }
APA
KOPYALA
Eleni Doulou,Marina Kalomiraki,Anthi Parla,Kyriaki Thermos,Nikos A. Chaniotakis,Irene Panderi. (2021). Hydrophilic Interaction Liquid Chromatography Coupled with Fluorescence Detection (HILIC-FL) for the Quantitation of Octreotide in Injection Forms (Vol. 2). Vol. 2. A Journal of Analytical Chemistry and Chemical Analysis.
MLA
KOPYALA
Eleni Doulou,Marina Kalomiraki,Anthi Parla,Kyriaki Thermos,Nikos A. Chaniotakis,Irene Panderi. Hydrophilic Interaction Liquid Chromatography Coupled with Fluorescence Detection (HILIC-FL) for the Quantitation of Octreotide in Injection Forms. no. 121–129, A Journal of Analytical Chemistry and Chemical Analysis, 2021.