European Endodontic Journal

European Endodontic Journal

Comparison of the Self-Adjusting File and Hedström File Used as Supplementary Instruments for the Remaining Filling Material Removal During Retreatment of C-Shaped Canals: A Micro-CT Study

Yazarlar: Pablo Andrés Amoroso Silva, Murilo Alcalde, Rodrigo Vivan, Marco Antonio Hungaro Duart

Cilt 5 , Sayı 2 , 2020 , Sayfalar  112 - 117

Konular:-

DOI:10.14744/eej.2020.50570

Anahtar Kelimeler: C-shaped canals,Hedström file,Micro-CT,Root canal retreatment,Reciproc,Self-adjusting file

Özet: The aim of this study was to evaluate the use of Self-adjusting file (SAF) system and Hedström (H) file for removing remaining filling material (RFM) from C-shaped canals. Methods: 20 C-shaped mandibular second molars with C1 configurations were instrumented, filled with tagger´s hybrid technique. Samples were divided into 2 groups (n=10). Reciproc R25 and a Mtwo 35/04 file were used for retreatment in both groups. Then, a 2.0 SAF file (group I) and a #35 H file (group II) were used as supplementary steps for RFM removal. Micro-CT scanning was performed after every procedure. Total volumes were calculated and converted into percentages. Also, the minimum wall thickness at 3, 5, 7 mm from apex was calculated. The Prism 7.0 software was used as the analytical tool with a significance of 5%. Results: Initial obturation removal was approximately 64% in group I and 67% in Group II. The apical third had the highest values of RFM. The use of a H file significantly reduced the RFM compared to SAF in the total canal length respectively (30% vs 18%) and at 1-3 mm and 3-6 mm when compared to the use of SAF. A statistically significant decrease of RFM and minimum wall thickness were observed in both groups (P<0.05). Conclusion: None of the retreatment techniques completely removed RFM. The apical region was the more unaffected area. Also, the SAF file was less effective than the H file in removing the RFM. Although C-shaped canals possesses thinner dentinal wall thickness, no excessive dentine removal was observed after each instrument use. (EEJ-2019-07-067)


ATIFLAR
Atıf Yapan Eserler
Henüz Atıf Yapılmamıştır

KAYNAK GÖSTER
BibTex
KOPYALA
@article{2020, title={Comparison of the Self-Adjusting File and Hedström File Used as Supplementary Instruments for the Remaining Filling Material Removal During Retreatment of C-Shaped Canals: A Micro-CT Study}, volume={5}, number={112–117}, publisher={European Endodontic Journal}, author={Pablo Andrés Amoroso Silva, Murilo Alcalde, Rodrigo Vivan, Marco Antonio Hungaro Duart}, year={2020} }
APA
KOPYALA
Pablo Andrés Amoroso Silva, Murilo Alcalde, Rodrigo Vivan, Marco Antonio Hungaro Duart. (2020). Comparison of the Self-Adjusting File and Hedström File Used as Supplementary Instruments for the Remaining Filling Material Removal During Retreatment of C-Shaped Canals: A Micro-CT Study (Vol. 5). Vol. 5. European Endodontic Journal.
MLA
KOPYALA
Pablo Andrés Amoroso Silva, Murilo Alcalde, Rodrigo Vivan, Marco Antonio Hungaro Duart. Comparison of the Self-Adjusting File and Hedström File Used as Supplementary Instruments for the Remaining Filling Material Removal During Retreatment of C-Shaped Canals: A Micro-CT Study. no. 112–117, European Endodontic Journal, 2020.