International Journal of Health and Clinical Research

International Journal of Health and Clinical Research

Analytical Method Development, Optimization and Validation of Combination of Azithromycin and Benzoyl Peroxide By RP-HPLC Using Design of Experiment as Per ICH Guideline

Yazarlar: Narendra Singh, Yogendra Singh, R. S. Bhadauria, Jeyabalan Govindasamy

Cilt 2 , Sayı 3 , 2019 , Sayfalar 26-45

Konular:-

Anahtar Kelimeler:Method validation,RP,PLC,Azithromycin & Benzoyl peroxide.

Özet: A simple, fast, accurate and precise RP-HPLC method were developed and validated for the estimation of Azithromycin & Benzoyl peroxide per ICH guidelines. Potassium dihydrogen phosphate and Acetonitrile (50:50) are commonly used as solvents. The method was developed in Eclipse C18 column (Waters XTerra®, 4.6Χ250 mm, particle 5μ) with Potassium dihydrogen phosphate and Acetonitrile are commonly used solvents in RP -HPLC having low UV cut- off of 200-400 nm respectively. In RP-HPLC method was found to be linear in the range of Azithromycin/Benzoyl peroxide is 1-5μg/ml with a correlation coefficient value of 0.99. The accuracy studies of RP-HPLC method was performed at three different levels, i.e., 80%, 100%. The limit of detection (LOD) and Limit of Quantification (LOQ) for Azithromycin 0.009μg/ml & 0.028μg/ml and for Benzoyl peroxide 0.015μg/ml & 0.046μg/ml is to be were found. The Percentage RSD should not be more than 2 which indicate the accuracy and precision of the method. Hence the method was robust.Thus this shows that the method is capable to give a good detector response, the recovery calculated was within the range of 98% to 101% of the specification limits. Hence the method was a rapid tool for routine analysis of Azithromycin/Benzoyl peroxide in the bulk and in the pharmaceutical dosage form.


ATIFLAR
Atıf Yapan Eserler
Henüz Atıf Yapılmamıştır

KAYNAK GÖSTER
BibTex
KOPYALA
@article{2019, title={Analytical Method Development, Optimization and Validation of Combination of Azithromycin and Benzoyl Peroxide By RP-HPLC Using Design of Experiment as Per ICH Guideline}, volume={2}, number={26–45}, publisher={International Journal of Health and Clinical Research}, author={Narendra Singh,Yogendra Singh,R. S. Bhadauria,Jeyabalan Govindasamy}, year={2019} }
APA
KOPYALA
Narendra Singh,Yogendra Singh,R. S. Bhadauria,Jeyabalan Govindasamy. (2019). Analytical Method Development, Optimization and Validation of Combination of Azithromycin and Benzoyl Peroxide By RP-HPLC Using Design of Experiment as Per ICH Guideline (Vol. 2). Vol. 2. International Journal of Health and Clinical Research.
MLA
KOPYALA
Narendra Singh,Yogendra Singh,R. S. Bhadauria,Jeyabalan Govindasamy. Analytical Method Development, Optimization and Validation of Combination of Azithromycin and Benzoyl Peroxide By RP-HPLC Using Design of Experiment as Per ICH Guideline. no. 26–45, International Journal of Health and Clinical Research, 2019.